UPS CAD10KX1-RT-4U

  • On-line Double Conversion technology
  • Equipped with high reliability advanced DSP microcontroller Fully digital controlled
  • IGBT technology or transformerless design
  • Works in frequency range of ±3Hz or ±5Hz (Ability to work with Generator)
  • Very low output voltage variations about 1% (Good regulation ability)
  • Ability to remove EMI and RFI noises
  • Capability of using isolation transformer on the output
  • Ability to bypass manually
  • High efficiency



یو پی اس آنلاین CAD10000 ONLINE-DOUBLE CONVERSION
یو پی اس آنلاین CAD10000 ONLINE-DOUBLE CONVERSIONیو پی اس آنلاین CAD10000 ONLINE-DOUBLE CONVERSIONیو پی اس آنلاین CAD10000 ONLINE-DOUBLE CONVERSIONیو پی اس آنلاین CAD10000 ONLINE-DOUBLE CONVERSIONیو پی اس آنلاین CAD10000 ONLINE-DOUBLE CONVERSION
Technical Specification
Technology
On Line - Double Conversion
Transfer time
0ms
Charger

Have

Efficiency

In normal mode:<92%

Nominal power

10000VA / 7000Watt

Input
Max current
50A
Phase

Single Phase

Frequency

50±3Hz / ±5Hz

Voltage(VAC)

170~270VAC

Output
Current

45.4A at non-linear full load

Phase

Single Phase

Nominal power factor
0.7
Overload capacity
 Up to 125% of nominal power for 10 seconds
150% of nominal power for 0.4 seconds
 
Voltage(Battery)

Pure Sine Wave 220VAC ±1%

THD

<2% at linear load / <5% at non-linear load

Frequency

In AC mode:50±3Hz or ±5Hz / In battery mode: 50±0.01Hz

Voltage(AC)

Pure Sine Wave 220VAC±1%

Battery
Recharge time

10 hours for 90% discharge

Internal battery

Doesn’t have

Voltage

240VDC

External battery

Special connector to external battery cabinet

Type

Sealed lead acid batteries with free maintenance

Environment
Altitude

1000 meters max. elevation (Based on IEC 62040)

Temperature

0~40ºC

Humidity

0~80% (Non-condensing)

Audible noise

at 1 meter from surface: <55dB

Dimension[W*D*H] (mm)
With base in order to stand on battery cabinet

192*687*440

Shipping Dimension

290*760*530

With handle

177*720*490

Weight (Kg)
Net weight (Kg)

24.9

Shipping weight (Kg)

27.5

  • Equipped with advanced DSP microcontroller with high reliability
  • Fully digital controlled
  • Ability to work with Generator
  • Good Regulation Ability
  • Ability to work in frequencies ±3HZ or ±5HZ
  • Ability to remove EMI and RFI Noises
  • Power Factor Correction
  • System modulated for better and easy Servicing
  • Equipped with External battery connector
  • Low weight and size
  • Includes Switch mode Charger
  • Equipped with Smart RS232 port
  • Equipped with Smart USB Port
  • Includes UPSwing Pro software for controlling and monitoring UPS, auto saving open files and shutdown OS and UPS in critical events
  • Includes Test Button for checking if UPS working properly in lack of AC line Voltage
  • Cold Start
  • Automatically Battery Charging in UPS standby mode
  • Ability to add UPS Device Managers as SNMP Cards
  • Ability to Bypass Manually in order to Service the UPS without turning the load off
  • Ability to recognize Battery disconnection
  • In Rack-mount models
  • Ability to adjust and control fan's speed
  • Lightning, spike and surge protection (Only in the case of using standard Earth)
  • Protection of UPS Loads against two phased AC line
  • Protection against output Voltage Variations out of range
  • Output Short circuit and overload Protection
  • Protection against Input Voltage and Frequency Variations
  • Protection against high impedance of AC line
  • Over Heat Protection
  • Common Mode Noise Protection
  • Reversed battery connection Protection
  • Charger Short circuit Protection
  • Protection against over-discharge
  • Battery Terminal Short circuit Protection
  • Protection against Upper Battery Charger Voltage
  • Positive back feed Protection
Audio Alarms
  • Battery Mode (Power Failure)
  • Battery Low
  • UPS Fault
  • High Battery or Charger Voltage in AC Line Mode
  • Over Load
  • Going to Sleep or Shutdown mode
  • Testing UPS
  • Earth Fault
  • Site Wiring Fault (Earth & Null)
  • Over Heat
Visual Alarms
  • Battery Mode (Power Failure)
  • AC Line Mode
  • Battery Level Indicators
  • Short circuit and Overload
  • Load Level Indicators
  • Battery Low
  • Input Voltage or Frequency Variations out of range
  • Protection against Over-charge
  • Battery Defect
  • UPS Fault
  • Over Heat
  • Normal Input Voltage
  • By Pass Mode
  • Earth Fault
  • Site Wiring Fault (Earth & Null)
  • Sleep Mode