UPS CAD10KX3-RT-4U

  • On-line Double Conversion technology
  • Equipped with high reliability advanced DSP microcontroller Fully digital controlled
  • IGBT technology or transformerless design
  • Works in frequency range of ±3Hz or ±5Hz (Ability to work with Generator)
  • Very low output voltage variations about 1% (Good regulation ability)
  • Ability to remove EMI and RFI noises
  • Capability of using isolation transformer on the output
  • Ability to bypass manually
  • High efficiency



یو پی اس 3 فاز کادیلاک فاراتل - cadillac 3x
یو پی اس 3 فاز کادیلاک فاراتل - cadillac 3xیو پی اس 3 فاز کادیلاک فاراتل - cadillac 3xیو پی اس 3 فاز کادیلاک فاراتل - cadillac 3x
Technical Specification
Technology

On-Line Double Conversion

Efficiency

In normal mode:<91%

Transfer time

0msec

Charger

Have

Nominal power

10000VA / 7000Watt

Input
Voltage(VAC)

Max current
Single Phase: 50A / Three Phase: 25A

 

Phase

Single phase (1Ph+N+PE)/Three phase (3Ph+N+PE)

Frequency

50±3Hz / ±5Hz

Output
Voltage(AC)

Pure Sine Wave 220VAC ±1%

Current

45.4A at non-linear full load

Phase

Single phase

Nominal power factor

0.7

THD

<2% at linear load / <5% at non-linear load

Overload capacity
Up to 125% of nominal power for 10 seconds
150% of nominal power for 0.4 seconds
Voltage(Battery)

Pure Sine Wave 220VAC ±1%

Frequency

In AC mode:50±3Hz or ±5Hz / In battery mode: 50±0.01Hz

Battery
Type

Sealed lead acid batteries with free maintenance

Internal battery

Doesn’t have

Recharge time

10 hours for 90% discharge

External battery

Equipped with external battery connector

Voltage

240VDC

Environment
Audible noise

at 1 meter from surface: <60dB

Temperature

0 ~ 40ºC

Altitude

1000 meters max. elevation (Based on IEC 62040)

Humidity

0~80% (Non-condensing)

Dimension[W*D*H] (mm)
With base in order to stand on battery cabinet

192*687*440

With handle

177*720*490

Shipping Dimension

290*760*530

Weight (Kg)
Net weight (Kg)

27

Shipping weight (Kg)

29.5

  • Equipped with advanced DSP microcontroller with high reliability
  • Fully digital controlled
  • Ability to work with Generator
  • Good Regulation Ability
  • Ability to work in frequencies ±3HZ or ±5HZ
  • Ability to remove EMI and RFI Noises
  • Power Factor Correction
  • System modulated for better and easy Servicing
  • Equipped with External battery connector
  • Low weight and size
  • Includes Switch mode Charger
  • Equipped with Smart RS232 port
  • Equipped with Smart USB Port
  • Includes UPSwing Pro software for controlling and monitoring UPS, auto saving open files and shutdown OS and UPS in critical events
  • Includes Test Button for checking if UPS working properly in lack of AC line Voltage
  • Cold Start
  • Automatically Battery Charging in UPS standby mode
  • Ability to Bypass Manually in order to Service the UPS without turning the load off
  • Ability to recognize Battery disconnection
  • Ability to adjust and control fan's speed
  • Lightning, spike and surge protection (Only in the case of using standard Earth)
  • Protection of UPS Loads against two phased AC line
  • Output Short circuit and overload Protection
  • Protection against Input Voltage and Frequency Variations
  • Protection against high impedance of AC line
  • Over Heat Protection
  • Common Mode Noise Protection
  • Reversed battery connection Protection
  • Charger Short circuit Protection
  • Protection against over-discharge
  • Battery Terminal Short circuit Protection
  • Protection against Upper Battery Charger Voltage
  • Positive back feed Protection
Audio Alarms
  • Battery Mode (Power Failure)
  • Battery Low
  • UPS Fault
  • High Battery or Charger Voltage in AC Line Mode
  • Over Load
  • Reversed battery connection
  • Going to Sleep or Shutdown mode
  • Testing UPS
  • Site Wiring Fault (Earth & Null)
  • Over Heat
Visual Alarms
  • Battery Mode (Power Failure)
  • AC Line Mode
  • Battery Level Indicators
  • Short circuit and Overload
  • Load Level Indicators
  • Battery Low
  • Input Voltage or Frequency Variations out of range
  • Protection against Over-charge
  • Battery Defect
  • UPS Fault
  • Over Heat
  • Normal Input Voltage
  • By Pass Mode
  • Site Wiring Fault (Earth & Null)
  • Sleep Mode