UPS DSS2000X-RT 

  • Smart On-Line Double Conversion
  • IGBT technology
  • Ability to work with generator
  • Ability to remove EMI and RFI noises
  • High efficiency
  • Equipped with intelligent microcontroller
  • Very low output voltagevariations about ±1%



یو پی اس لاین اینتراکتیو DSS2000
یو پی اس لاین اینتراکتیو DSS2000یو پی اس لاین اینتراکتیو DSS2000یو پی اس لاین اینتراکتیو DSS2000یو پی اس لاین اینتراکتیو DSS2000
Technical Specification
Technology

Line-Interactive

Nominal power

2000VA / 2000Watt

Efficiency

In normal mode >95%

Transfer time

2-4msec

Charger

Have

Input
Max current

13A

Frequency

50±3Hz / 5Hz

Phase

Single phase

Voltage(VAC)
0%-70%LOAD(148~270 VAC)
70%-100%LOAD(170~270 VAC)
Output
Current

9.09A

Phase

Single phase

Nominal power factor

1

THD

At non–linear load <6%

Overload capacity

105%~125% of nominal power for 10 Seconds

Voltage(AC)

220VAC±10%

Voltage(Battery)

220VAC±1%

Frequency
In AC mode: synch with input
In battery mode: 50±0.01Hz
 
Battery
Type

Sealed lead acid batteries with free maintenance

Internal battery

Doesn’t have

Recharge time

10 hours for 90% discharge

External battery

Equipped with external battery connector

Voltage

48VDC

Environment
Audible noise

1000 Meters max. elevation (Based on IEC 62040)

Humidity

0~80% (Non-condensing)

Altitude

1000 Meters max. elevation (Based on IEC 62040)

Temperature

0~40ºC

Dimension[W*D*H] (mm)
Shipping Dimension

205*620*530

Net Dimension

88*512*440

With handle

90*542*483

Weight (Kg)
Net weight (Kg)

14.1

Shipping weight (Kg)

16.6

  • Common mode noise protection
  • Capability to work with generator
  • Ability to work with Generator
  • Equipped with Watchdog System
  • Ability to work in frequencies ±3HZ or ±5HZ
  • Ability to remove EMI and RFI Noises
  • System modulated for better and easy Servicing
  • Equipped with External battery connector
  • Low weight and size
  • Includes Switch mode Charger
  • Equipped with Smart RS232 port
  • Equipped with Smart USB Port
  • Includes UPSwing Pro software for controlling and monitoring UPS, auto saving open files and shutdown OS and UPS in critical events
  • Automatic battery test every 21 days
  • Automatically battery charging in UPS standby mode
  • Cold Start
  • Automatically Battery Charging in UPS standby mode
  • Ability to add UPS Device Managers as SNMP Cards
  • Ability to Bypass Manually in order to Service the UPS without turning the load off
  • Lightning surge protection
  • Load Protection against two-phased AC line
  • Protection of UPS Loads against Lightning, Spike and surge
  • Protection of UPS Loads against two phased AC line
  • Protection against output Voltage Variations out of range
  • Output Short circuit and overload Protection
  • Protection against Input Voltage and Frequency Variations
  • Over Heat Protection
  • Common Mode Noise Protection
  • Reversed battery connection Protection
  • Charger Short circuit Protection
  • Protection against over-discharge
  • Back Feed Protection on Battery Mode
  • Protection against Upper Battery Charger Voltage
  • Tel/Fax/Modem/Network surge suppression
Audio Alarms
  • Battery Low
  • Over Load
  • Testing UPS
  • Earth Fault
  • Over Heat
Visual Alarms
  • Battery Mode (Power Failure)
  • AC Line Mode
  • Short circuit and Overload
  • Battery Low
  • Protection against Over-charge
  • Over Heat
  • Normal Input Voltage
  • By Pass Mode
  • Earth Fault
  • Site Wiring Fault (Earth & Null)