Introduction of Product

Faratel Digital Smart Sine UPS series are designed based on line-Interactive technology and can provide pure sine wave in output independent of input AC line even in power failure.

Faratel DSS series are equipped with smart micro-processing system to check for proper operation of UPS and find probable errors in any part of that.

DSS series are designed for Computer systems, medical devices, Telecommunication or any other power sensitive devices.

 




Technical Specification
Technology

Line-Interactive

Nominal power

3000VA / 3000Watt

Efficiency

In normal mode >95%

Transfer time

2-4msec

Charger

Have

Input
Max current

20A

Frequency

50±3Hz / 5Hz

Phase

Single phase

Voltage(VAC)
0%-70%LOAD(148~270 VAC)
70%-100%LOAD(170~270 VAC)
Output
Current

13.63A

Phase

Single phase

Nominal power factor

1

THD

At non–linear load <5%

Overload capacity

105%~125% of nominal power for 10 Seconds

Voltage(AC)

220VAC±10%

Voltage(Battery)

220VAC±1%

Frequency

In AC mode: synch with input

In battery mode: 50±0.01Hz
 
Battery
Type

Sealed lead acid batteries with free maintenance

Internal battery

Doesn’t have

Recharge time

10 hours for 90% discharge

External battery

Equipped with external battery connector

Voltage

96VDC

Environment
Audible noise

at 1 meter from surface: <40dB

Altitude

1000 meters max. elevation (Based on IEC 62040)

Temperature

0~40ºC

Humidity

0~80% (Non-condensing)

Dimension[W*D*H] (mm)
Net Dimension

88*512*440

With handle

90*542*483

Shipping Dimension

205*620*530

Weight (Kg)
Net weight (Kg)

14.7

Shipping weight (Kg)

17.2

  • Capability to work with generator
  • Intelligent microprocessor controlled
  • Equipped with Watchdog System
  • Ability to remove EMI and RFI Noises
  • System modulated for better and easy Servicing
  • Low weight and size
  • Includes Switch mode Charger
  • Equipped with Smart RS232 port
  • Includes UPSwing Pro software for controlling and monitoring UPS, auto saving open files and shutdown OS and UPS in critical events
  • Includes Test Button for checking if UPS working properly in lack of AC line Voltage
  • Automatic battery test every 21 days
  • Automatically battery charging in UPS standby mode
  • Cold Start
  • Automatically Battery Charging in UPS standby mode
  • Ability to add UPS Device Managers as SNMP Cards
  • Lightning surge protection
  • Load Protection against two-phased AC line
  • Protection of UPS Loads against two phased AC line
  • Protection against output Voltage Variations out of range
  • Output Short circuit and overload Protection
  • Protection against Input Voltage and Frequency Variations
  • Over Heat Protection
  • Common Mode Noise Protection
  • Reversed battery connection Protection
  • Charger Short circuit Protection
  • Protection against over-discharge
  • Back Feed Protection on Battery Mode
  • Protection against Upper Battery Charger Voltage
  • Tel/Fax/Modem/Network surge suppression
Audio Alarms
  • Battery Mode (Power Failure)
  • Battery Low
  • Over Load
  • Earth Fault
  • Over Heat
Visual Alarms
  • Battery Mode (Power Failure)
  • AC Line Mode
  • Short circuit and Overload
  • Battery Low
  • Input Voltage or Frequency Variations out of range
  • Protection against Over-charge
  • Over Heat
  • Normal Input Voltage
  • Earth Fault