UPS VENUS1300

  • Line interactive technology
  • Equipped with intelligent  microprocessor control system
  • Ability to remove EMI and RFI noises
  • System modulated (Better and easy servicing)
  • Equipped with Sealed Lead Acid batteries (Maintenance free)
  • Battery management
  • Low weight



Technical Specification
Technology
Line - Interactive
Nominal power
1300VA-780Watt
Transfer time
2.5msec
Internal battery
2
Charger

Have

Efficiency

95% <

Input
Voltage(VAC)
220VAC±20%
Phase

Single Phase

Max current

8A

Frequency

50±3Hz / ±5Hz

Output
Phase

Single Phase

Nominal power factor
0.6
Voltage(Battery)

220Vr.m.s±5% Quasi-Sine Wave

Frequency

AC mode: synch with input / Battery mode: 50Hz±0.2%

Overload capacity
110%~130% of nominal power for 1 minute
More than 130% of nominal power for 3 seconds
Current

5.9A

Voltage(AC)

220VAC±10% Sine Wave

Battery
Recharge time

10 hours for 90% discharge

Voltage

24VDC

Type

Sealed lead acid batteries with free maintenance

Internal battery

2 Batteries 12V

Environment
Temperature
0-40̊C
Altitude

1000 Meters max. elevation (Based on IEC62040)

Humidity

0~80% (Non-condensing)

Dimension[W*D*H] (mm)
Shipping Dimension

250*460*180

Net Dimension

169*385*140

Weight (Kg)
Net weight (Kg)

14.6

Shipping weight (Kg)

15.6

  • Intelligent microprocessor controlled
  • Ability to remove EMI and RFI Noises
  • System modulated for better and easy Servicing
  • Low weight and size
  • Equipped with Smart RS232 port
  • Includes UPSwing Pro software for controlling and monitoring UPS, auto saving open files and shutdown OS and UPS in critical events
  • Contains Sealed Lead-Acid Batteries
  • Includes Test Button for checking if UPS working properly in lack of AC line Voltage
  • Cold Start
  • Automatically Battery Charging in UPS standby mode
  • Lightning, spike and surge protection (Only in the case of using standard Earth)
  • Protection of UPS Loads against two phased AC line
  • Protection against output Voltage Variations out of range
  • Output Short circuit and overload Protection
  • Protection against Input Voltage and Frequency Variations
  • Common Mode Noise Protection
  • Protection against over-discharge
  • Back Feed Protection on Battery Mode
  • Protection against Upper Battery Charger Voltage
  • Tel/Fax/Modem/Network surge suppression
Audio Alarms
  • Battery Mode (Power Failure)
  • Battery Low
  • High Battery or Charger Voltage in AC Line Mode
  • Over Load
  • Going to Sleep or Shutdown mode
  • Testing UPS
  • Site Wiring Fault (Earth & Null)
Visual Alarms
  • Battery Mode (Power Failure)
  • AC Line Mode
  • Short circuit and Overload
  • Battery Low
  • Input Voltage or Frequency Variations out of range
  • Protection against Over-charge
  • Battery Defect
  • Normal Input Voltage
  • Sleep Mode